ELECTRICAL UNIT DANFOSS_SECOP 101N0212 B
12/24V Electronic module for all Danfoss and SECOP BD35 and BD50 Compressors.
For all Isotherm units since 1998, connects to the compressor with three pins.
This is the latest version of the DC module for BD35 and BD50 compressors, it is a direct replacement for Part number 101N0210.
Tech tip: to test this module, put a jumper between the T (Thermostat) and C (Compressor) terminals. The compressor should start and run at low speed. If the compressor doesn't start, you may need to replace this module. We can test the module for you here, please call for details.
101N0210, 101N0220, 101N0230, 101N0240, 101N0250, 101N0260 101N0600, 101N0630, 101N0650
SECOP part number #101N0212, Frigoboat part E50896.
Case size: 2 5/8" x 4 1/8" x 1 3/4"
INDEL Part #SEG00002DA